Introduction to Measurement of External Liquid Level Gauge Horizontal Tank (Liquid Chlorine) in a Salt Industry Company in Shandong 123
The customer's site is a horizontal liquid chlorine storage tank. After comparing with multiple peer products, we ultimately chose our company's external mounted liquid level instrument. The stable performance, automatic calibration, and maintenance free features greatly save the workload of instrument staff and have received unanimous praise from the on-site team. The parameters of the on-site horizontal tank liquid level instrument are as follows:;
Model: SER-YW (Explosion proof), (Two wire system), (No blind spots)
Probe cable length: 15M
Tank type: Ball tank
Measurement range: 0-5000 mm
Output signal: 4-20 mA DC+HART
Power supply: 24V
Temperature: -50 °~80 ° C
Wiring method: two-wire system
Display resolution: 1mm
Short term repeatability: 1mm
Measurement error: ± 0.1% FS
Probe usage environment temperature: -50 ℃ to+80 ℃
Operating environment humidity: 15% to 100% RH
Liquid level display: LCD display
Calibration equipment: with calibration probe
Special requirement: SIL3 certification
Protection level: IP67;
Explosion proof grade: Exd Ⅱ CT6Gb;
Installation method: magnetic suction