Introduction to the measurement of a new material external liquid level gauge horizontal tank (hydrogen fluoride) in Jiangxi Province
There are more than 20 horizontal HF (hydrogen fluoride) storage tanks on the customer's site. After confirming the working conditions with the technical engineer on site, we finally chose our company's externally mounted liquid level instrument with temperature calibration. Perfectly solve the interference of temperature changes on liquid level monitoring in storage tanks. Advanced technology, two-wire installation is more convenient, and there is no need to rewire on site, saving a lot of manpower and material resources. The parameters of the on-site horizontal tank liquid level instrument are as follows:;
Model: SER-YW (explosion-proof type), (two-wire system), (temperature calibration)
Probe cable length: 15M
Tank Type: Horizontal Tank
Measurement range: 0-5000 mm
Output signal: 4-20 mA DC+HART
Power supply: 24V
Temperature: -50 °~80 ° C
Wiring method: two-wire system
Display resolution: 1mm
Measurement error: ± 0.1% FS
Probe usage environment temperature: -50 ℃ to+80 ℃
Operating environment humidity: 15% to 100% RH
Explosion proof mark: Exd Ⅱ CT6
Liquid level display: LCD display
Calibration equipment: with calibration probe
Special requirement: SIL3 certification
Protection level: IP67;
Explosion proof grade: Exd Ⅱ CT6Gb;
Installation method: magnetic suction